membrane covered sensor for free chlorine
Special features
• for high salt concentrations
• short response time
• simple usage
Applications
Brine- and sea water
Process conditions
• stable pH value
• No surfactants in the measuring water
• max. temperature: 45 °C
• max. pressure: 1 bar
• 3.5% to 26% salt content in sample water
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for free chlorine
Special features
• short response time
• simple usage
Applications
Swimming pool-, drinking-, service- and process water
Process conditions
• stable pH value
• No surfactants in the measuring water
• max. temperature: 45 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for free chlorine in presence of cyanuric acid
Special features
• reduced pH dependence
• tolerates surfactants
• low maintenance
• tolerates low conductivity
Applications
Swimming pool-, drinking-, service-, process- and sea water
Process conditions
• max. temperature: 45 °C
• max. pressure: 3 bar
• min. conductivity: 10 μS/cm
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for total chlorine
Special features
• reduced pH dependence
• tolerates surfactants
• low maintenance
• tolerates low conductivity
Applications
Swimming pool-, drinking-, service-, process-, sea- and brine water
Process conditions
• max. temperature: 45 °C
• max. pressure: 3 bar
• min. conductivity: 10 μS/cm
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for free chlorine
Special features
• reduced pH dependence
• tolerates surfactants
• low maintenance
• tolerates low conductivity
Applications
Swimming pool-, drinking-, service-, process- and sea water
Process conditions
• max. temperature: 45 °C
• max. pressure: 3 bar
• min. conductivity: 10 μS/cm
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
sensor for free chlorine without covering membranes
Special features
• for high pressures
• short response time
• tolerates surfactants
• reduced maintenance effort due to automatic electrode cleaning with RV1 (optional)
Applications
Drinking water
Process conditions
• stable pH value
• max. temperature: 50 °C
• max. pressure: 8 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
sensor for free chlorine without covering membranes
Special features
• for high water temperatures
• for high pressures
• short response time
• tolerates surfactants
• reduced maintenance effort due to automatic electrode cleaning with RV1 (optional)
Applications
Drinking- and hot water applications (e.g. legionella control)
Process conditions
• stable pH value
• max. temperature: 70 °C
• max. pressure: 8 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for free chlorine
Special features
• for high chlorine concentrations up to 2000 ppm
• mechanically robust membrane system
• tolerates surfactants
• high level of tolerance to chemicals
• tolerates dirty sample water
Applications
Washing of fruit, vegetables and poultry, service- and process water
Process conditions
• stable pH value
• max. temperature: 45 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for free chlorine
Special features
• Certificated ATEX und IECEx
• reduced pH dependence
• tolerates surfactants
• low maintenance
Applications
Sea and ballast water
Process conditions
• max. temperature: 45 °C
• max. pressure: 0,5 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for chlorine dioxide
Special features
• short response time
Applications
Swimming pool-, drinking-, service- and process water
Process conditions
• No surfactants in the measuring water
• max. temperature: 45 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
sensor for chlorine dioxide without covering membranes
Special features
• for high pressures
• short response time
• tolerates surfactants
Applications
Drinking water
Process conditions
• max. temperature: 50 °C
• max. pressure: 8 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
sensor for chlorine dioxide without covering membranes
Special features
• for high water temperatures
• for high pressures
• short response time
• tolerates surfactants
Applications
Drinking- and hot water applications (e.g. legionella control)
Process conditions
• max. temperature: 70 °C
• max. pressure: 8 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for chlorine dioxide
Special features
• mechanically robust membrane system
• tolerates surfactants
• high level of tolerance to chemicals
Applications
All types of water treatment
Process conditions
• max. temperature: 50 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for peracetic acid
Special features
• for high water temperatures
• mechanically robust membrane system
• tolerates surfactants
• high level of tolerance to chemicals
• low cross-sensitivity to hydrogen peroxide
Applications
All types of water treatment
Process conditions
• max. temperature: 60 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for peracetic acid
Special features
• mechanically robust membrane system
• tolerates surfactants
• high level of tolerance to chemicals
• low cross-sensitivity to hydrogen peroxide
Applications
All types of water treatment
Process conditions
• max. temperature: 45 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for ozone
Special features
• short response time
• simple usage
Applications
Swimming pool-, drinking-, service- and process water
Process conditions
• No surfactants in the measuring water
• max. temperature: 45 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for ozone
Special features
• mechanically robust membrane system
• tolerates surfactants
• high level of tolerance to chemicals
Applications
All types of water treatment
Process conditions
• max. temperature: 45 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for hydrogen peroxide
Special features
• mechanically robust membrane system
• tolerates surfactants
Applications
All types of water treatment
Process conditions
• max. temperature: 45 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for hydrogen peroxide
Special features
• mechanically robust membrane system
• tolerates surfactants
• high level of tolerance to chemicals
Applications
All types of water treatment
Process conditions
• max. temperature: 45 °C
• max. pressure: 1 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for free bromine and BCDMH
Special features
• reduced pH dependence
• tolerates surfactants
Applications
Swimming pool-, drinking-, service-, process- and sea water
Process conditions
• max. temperature: 45 °C
• max. pressure: 0,5 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
membrane covered sensor for chlorite
Special features
• tolerates surfactants
• no cross-sensitivity for chlorine dioxide, chlorine, chlorate
Applications
Swimming pool-, drinking-, service- and process water
Process conditions
• max. temperature: 40 °C
• max. pressure: 5 bar
Further technical information can be found in the data sheet and in the operating instruction.
Here you can download our latest flyer.
© Reiss GmbH · All rights reserved